Select the thermocouple type (K, J, E, and T) for the initial setting. (The type K is factory-set at shipment)

YOKOGAWA TX10 시리즈 디지털 써모미터 이미지

Select the thermocouple type (K, J, E, and T) for the initial setting. (The type K is factory-set at shipment)

원산지JAPAN
제조사YOKOGAWA
브랜드YOKOGAWA
무게1kg

Model Numbers

ModelDescription
TX10-011 input channel, -200.0 deg C to 199.9 deg C: 0.1 deg C 200 deg C or above: 1 deg C, 1 sec, N/A
TX10-021 input channel, -200.0 deg C to 199.9 deg C: 0.1 deg C or 1 deg C (when 1 deg C resolution is set) +200 deg C or above: 1 deg C, 1 sec, Capable of storing up to 10 measured data items
TX10-032 input channels, -200.0 deg C to 199.9 deg C: 0.1 deg C or 1 deg C (when 1 deg C resolution is set) +200 deg C or above: 1 deg C, 2 sec, Capable of storing up to 10 measured data items

Specifications - Model TX10-01

Number of Input channel

1
Measuring RangeType E: -200 to 700°C (-328 to 1292°F)
Type J: -200 to 1000°C (-328 to 1832°F)
Type K: -200 to 1372°C (-328 to 2501.6°F)
Type T: -200 to 400°C (-328 to 752°F)
Resolution-200.0°C to 199.9°C: 0.1°C
200°C or above: 1°C
Accuracy+200 °C or above, or when 1°C resolution is set ±(0.2% of rdg + 1°C)
-100.0°C to 199.9°C ±(0.1% of rdg + 0.7°C)
-200.0°C to -100.1°C ±(0.1% of rdg + 1.0°C)
Temperature Coefficient± (0.015% of rdg +0.06°C)/°C
Approx. Measurement Interval1 sec
Display ItemHOLD, °C, ch A, TC type K, J, E, T, Battery alarm
Other FunctionsAuto power-off, battery alarm
DisplayLCD
Operating Temperature0 to 50 ºC
Humidity80% RH (no condensation)
Power RequirementsTwo AA-size alkaline dry batteries (LR6)
Battery LifeAbout 450 hours
Drip-proof ConstructionConforms to IP54 (dust-proof and drip-proof requirements of IEC529)
Compliance with StandardsEMC Standards
EMI (interference signal): EN55011;1998, EN61326-1;1998+A1 (Class B, Group 1)
EMS (immunity): EN50082-1;1997, EN61326;1998+A1
Approx. Height151 mm
Approx. Width56 mm
Approx. Depth33 mm
Approx. External Weight180 g
Supplied AccessoriesTwo AA-size alkaline dry batteries (LR6) and instruction manual
Optional AccessoriesExtension Cable 5 m (2459 21)/10 m (2459 22)
Soft case (930 12)
Temperature Probes (for K type thermocouple)
Rounded end probe (900 20B, 900 21B, 900 22B)
Needle probe (900 23B, 900 24B)
Surface probe (900 30B, 900 31B, 900 32B, 900 33B)
Bead TC (2459 07)
Waterproof Cover (5-per package) (930 11)

Applications

  • Temperature management in a refrigerated warehouse
  • Frozen food products quality control
  • Perishable foods quality control
  • Temperature management in production processes
  • Product temperature measurement test
  • Temperature checks in equipment maintenance
  • Temperature management for research and development

Features

  • TC Type

Select the thermocouple type (K, J, E, and T) for the initial setting. (The type K is factory-set at shipment)

  • Operation
    Press and hold down the TC TYPE key while pressing the POWER key. The TX10 enters the thermocouple type selection mode, and each press of the TC TYPE key switches between the thermocouple types. Then accept the setting with the POWER key. (Make sure that the characters in the display have changed.)
  • Data Hold
    Press this key to hold the measured value.

Specifications - Model TX10-02

Number of Input channel

1
Measuring RangeType E: -200 to 700°C (-328 to 1292°F)
Type J: -200 to 1000°C (-328 to 1832°F)
Type K: -200 to 1372°C (-328 to 2501.6°F)
Type T: -200 to 400°C (-328 to 752°F)
Resolution-200.0°C to 199.9°C: 0.1°C or 1°C (when 1°C resolution is set)
+200°C or above: 1°C
Accuracy+200 °C or above, or when 1°C resolution is set ±(0.2% of rdg + 1°C)
-100.0°C to 199.9°C ±(0.1% of rdg + 0.7°C)
-200.0°C to -100.1°C ±(0.1% of rdg + 1.0°C)
Temperature Coefficient± (0.015% of rdg +0.06°C)/°C
Approx. Measurement Interval1 sec
Data StorageCapable of storing up to 10 measured data items
Simplified CorrectionCorrection range: ±20°C of measured value
Display ItemHOLD, RCD, REL, ADJ, MAX, MIN, MEM, °C chA, TC type K, J, E, T Battery alarm
Other FunctionsAuto power-off, battery alarm
DisplayLCD
Operating Temperature0 to 50 ºC
Humidity80% RH (no condensation)
Power RequirementsTwo AA-size alkaline dry batteries (LR6)
Battery LifeAbout 450 hours
Drip-proof ConstructionConforms to IP54 (dust-proof and drip-proof requirements of IEC529)
Compliance with StandardsEMC Standards
EMI (interference signal): EN55011;1998, EN61326-1;1998+A1 (Class B, Group 1)
EMS (immunity): EN50082-1;1997, EN61326;1998+A1
Approx. Height151 mm
Approx. Width56 mm
Approx. Depth33 mm
Approx. External Weight180 g
Supplied AccessoriesTwo AA-size alkaline dry batteries (LR6) and instruction manual
Optional AccessoriesExtension Cable 5 m (2459 21)/10 m (2459 22)
Soft case (930 12)
Temperature Probes (for K type thermocouple)
Rounded end probe (900 20B, 900 21B, 900 22B)
Needle probe (900 23B, 900 24B)
Surface probe (900 30B, 900 31B, 900 32B, 900 33B)
Bead TC (2459 07)
Waterproof Cover (5-per package) (930 11)

Applications

  • Temperature management in a refrigerated warehouse
  • Temperature checks in equipment maintenance
  • Temperature management for research and development

Features

  • Memory-in Function

Up to ten data items can be stored. When recalled, the stored data value is displayed with its memory number.

  • User calibration function
    Calibration and adjustment can be mode easily by operating the panel keys on instrument and a measurement-standard.
  • Thermocouple type (K, J, E, and T) select key
  • Input channel select key
    With each press, the channel switches through the sequence of "chA," "chB," and then "chA-chB."
  • Data hold key
    A held measured value, can be stored in the memory of an optional memory number, which is selected with the up, down keys.
  • Maximum and minimum record key
    Stores the maximum and minimum values from the time the RECORD key is pressed.
  • Data record key
    Stores the held measured value in memory. (Up to ten)
  • Resolution select key
    With each press, resolution alternates between 0.1ºC and 1ºC. (Within the range of -200.0ºC to 199.9ºC)
  • Maximum and minimum values, and stored data read key
    Every time this key is pressed, the maximum and minimum values, stored data, and the current measured data are displayed in sequence.
  • Relative display select key
    Displays measured values with reference to the value obtained immediately before this key was pressed (relative value). Each press of this key can select or release the relative display.
  • Simplified correction mode key
    Sets the correction value, and selects active/inactive of the simplified correction function.
  • Data call-up key
    Used to select a memory number when calling up stored data. Also used to adjust the correction value for simplified correction mode.

Specifications - Model TX10-03

Number of Input channel

2
Measuring RangeType E: -200 to 700°C (-328 to 1292°F)
Type J: -200 to 1000°C (-328 to 1832°F)
Type K: -200 to 1372°C (-328 to 2501.6°F)
Type T: -200 to 400°C (-328 to 752°F)
Resolution-200.0°C to 199.9°C: 0.1°C or 1°C (when 1°C resolution is set)
+200°C or above: 1°C
Accuracy+200 °C or above, or when 1°C resolution is set ±(0.2% of rdg + 1°C)
-100.0°C to 199.9°C ±(0.1% of rdg + 0.7°C)
-200.0°C to -100.1°C ±(0.1% of rdg + 1.0°C)
Temperature Coefficient± (0.015% of rdg +0.06°C)/°C
Approx. Measurement Interval2 sec
Data StorageCapable of storing up to 10 measured data items
Simplified CorrectionCorrection range: ±20°C of measured value
Display ItemHOLD, RCD, REL, ADJ, MAX, MIN, MEM, °C chA, chB, chA-chB TC type K, J, E, T Battery alarm
Other FunctionsAuto power-off, battery alarm
DisplayLCD
Operating Temperature0 to 50 ºC
Humidity80% RH (no condensation)
Power RequirementsTwo AA-size alkaline dry batteries (LR6)
Battery LifeAbout 450 hours
Drip-proof ConstructionConforms to IP54 (dust-proof and drip-proof requirements of IEC529)
Compliance with StandardsEMC Standards
EMI (interference signal): EN55011;1998, EN61326-1;1998+A1 (Class B, Group 1)
EMS (immunity): EN50082-1;1997, EN61326;1998+A1
Approx. Height151 mm
Approx. Width56 mm
Approx. Depth33 mm
Approx. External Weight180 g
Supplied AccessoriesTwo AA-size alkaline dry batteries (LR6) and instruction manual
Optional AccessoriesExtension Cable 5 m (2459 21)/10 m (2459 22)
Soft case (930 12)
Temperature Probes (for K type thermocouple)
Rounded end probe (900 20B, 900 21B, 900 22B)
Needle probe (900 23B, 900 24B)
Surface probe (900 30B, 900 31B, 900 32B, 900 33B)
Bead TC (2459 07)
Waterproof Cover (5-per package) (930 11)

Applications

  • Temperature management in a refrigerated warehouse
  • Temperature checks in equipment maintenance
  • Temperature management for research and development

Features

  • Memory-in Function

Up to ten data items can be stored. When recalled, the stored data value is displayed with its memory number.

  • User calibration function
    Calibration and adjustment can be mode easily by operating the panel keys on instrument and a measurement-standard.
  • Thermocouple type (K, J, E, and T) select key
  • Input channel select key
    With each press, the channel switches through the sequence of "chA," "chB," and then "chA-chB."
  • Data hold key
    A held measured value, can be stored in the memory of an optional memory number, which is selected with the up, down keys.
  • Maximum and minimum record key
    Stores the maximum and minimum values from the time the RECORD key is pressed.
  • Data record key
    Stores the held measured value in memory. (Up to ten)
  • Resolution select key
    With each press, resolution alternates between 0.1ºC and 1ºC. (Within the range of -200.0ºC to 199.9ºC)
  • Maximum and minimum values, and stored data read key
    Every time this key is pressed, the maximum and minimum values, stored data, and the current measured data are displayed in sequence.
  • Relative display select key
    Displays measured values with reference to the value obtained immediately before this key was pressed (relative value). Each press of this key can select or release the relative display.
  • Simplified correction mode key
    Sets the correction value, and selects active/inactive of the simplified correction function.
  • Data call-up key
    Used to select a memory number when calling up stored data. Also used to adjust the correction value for simplified correction mode.

Accessories

  • 90020B -50 to 600°C (rounded end)
    90021B -50 to 600°C (rounded end)
    90022B -50 to 600°C (rounded end)
    90023B -50 to 500°C (needle)
    90024B -50 to 500°C (needle)
    90029B -40 to 260°C (Bead TC)
  • 90030B -20 to 250°C (Surface straight)
    90031B -20 to 250°C (Surface angled)
    90032B -20 to 500°C (Surface straight)
    90033B -20 to 500°C (Surface angled)