Model Numbers Model Model Model 2011 31 2013 03 2013 17 2011 32 2013 04 2013 18 2011 33 2013 06 2013 19 2011 34 2013 07 2014 00 2011 35 2013 08 2017 30 2011 36 2013 09 2038 31 2011 37 2013 10 2038 32 2011 38 2013 11 2039 02 2011 39 2013 12 2039 03 2011 40 2013 13 2041 02 2011 41 2013 14 2041 03 2021

YOKOGAWA 2011 ~ 2053 휴대용 지시계 이미지

Model Numbers Model Model Model 2011 31 2013 03 2013 17 2011 32 2013 04 2013 18 2011 33 2013 06 2013 19 2011 34 2013 07 2014 00 2011 35 2013 08 2017 30 2011 36 2013 09 2038 31 2011 37 2013 10 2038 32 2011 38 2013 11 2039 02 2011 39 2013 12 2039 03 2011 40 2013 13 2041 02 2011 41 2013 14 2041 03 2021

원산지JAPAN
제조사YOKOGAWA
브랜드YOKOGAWA
무게1kg

Model Numbers

ModelModelModel
2011 312013 032013 17
2011 322013 042013 18
2011 332013 062013 19
2011 342013 072014 00
2011 352013 082017 30
2011 362013 092038 31
2011 372013 102038 32
2011 382013 112039 02
2011 392013 122039 03
2011 402013 132041 02
2011 412013 142041 03
2021 002013 152042 02
2013 012013 162042 03
ModelDescription
2051 110.15/0.5/1.5/5/15 mA DC, Permanent magnet moving coil type, JIS C 1102 : 1997 Class 1.0
2051 150.15/0.5/1.5/5/15 A DC, Permanent magnet moving coil type, JIS C 1102 : 1997 Class 1.0
2051 0310/30/100/300/1000 mA DC, Permanent magnet moving coil type, JIS C 1102 : 1997 Class 1.0
2051 203/10/30/100/300 V DC, Permanent magnet moving coil type, JIS C 1102 : 1997 Class 1.0
2053 035/10/25 A, Moving iron type, JIS C 1102 : 1997 Class 1.5
2051 135/15/50/150/500 mA DC, Permanent magnet moving coil type, JIS C 1102 : 1997 Class 1.0
2051 1410/30/100/300/1000 mA DC, Permanent magnet moving coil type, JIS C 1102 : 1997 Class 1.0
2051 120.3/1/3/10/30 mA DC, Permanent magnet moving coil type, JIS C 1102 : 1997 Class 1.0
2051 160.3/1/3/10/30 A DC, Permanent magnet moving coil type, JIS C 1102 : 1997 Class 1.0
2052 0775/150/300 V AC, Rectifier type (approximating RMS rectifier type for 15~300V), JIS C 1102 : 1997 Class 1.5
2053 010.25/0.5/1 A AC, Moving iron type, JIS C 1102 : 1997 Class 1.5
2053 021/2 5/5 A AC, Moving iron type, JIS C 1102 : 1997 Class 1.5
2052 022.5/5/10 mA AC, Rectifier type (approximating RMS rectifier type for 15~300V), JIS C 1102 : 1997 Class 1.5
2052 010.5/1/2.5 mA AC, Rectifier type (approximating RMS rectifier type for 15~300V), JIS C 1102 : 1997 Class 1.5
2052 0615/30/75 V AC, Rectifier type (approximating RMS rectifier type for 15~300V), JIS C 1102 : 1997 Class 1.5
2052 0450/100/250 mA AC, Rectifier type (approximating RMS rectifier type for 15~300V), JIS C 1102 : 1997 Class 1.5
2051 040.3/1/3/10/30 A DC, Permanent magnet moving coil type, JIS C 1102 : 1997 Class 1.0
2051 020.3/1/3/10/30 mA DC, Permanent magnet moving coil type, JIS C 1102 : 1997 Class 1.0
2051 050.3/1/3/10/30 V DC, Permanent magnet moving coil type, JIS C 1102 : 1997 Class 1.0
2051 063/10/30/100/300 V DC, Permanent magnet moving coil type, JIS C 1102 : 1997 Class 1.0
2051 170.15/0.5/1.5/5/15 V DC, Permanent magnet moving coil type, JIS C 1102 : 1997 Class 1.0
2052 0310/25/50 mA AC, Rectifier type (approximating RMS rectifier type for 15~300V), JIS C 1102 : 1997 Class 1.5
2052 053/7.5/15 V AC, Rectifier type (approximating RMS rectifier type for 15~300V), JIS C 1102 : 1997 Class 1.5
2051 0130/100/300/1000/3000 V A DC, Permanent magnet moving coil type, JIS C 1102 : 1997 Class 1.0
2051 180.3/1/3/10/30 V DC, Permanent magnet moving coil type, JIS C 1102 : 1997 Class 1.0
2051 191.5/5/15/50/150 V DC, Permanent magnet moving coil type, JIS C 1102 : 1997 Class 1.0

Specifications - Model 2051 01

Max. Scale Value

30/100/300/1000/3000 µA DC
Approximate Internal Resistance and Consumed Power5/6.8/2.8/0.9/0.3 kΩ
Operating PrinciplePermanent magnet moving coil type
ClassJIS C 1102: 1997 Class 1.0
Operating PositionHorizontal
Scale LengthApproximately 135 mm (Deflection Angle: 90°)
NeedleBladed Needle (red)
Linemax250V (Ammeters only)
Operating Temperature Range0 ~ 40 ºC
Operating Humidity Range30 ~ 75% RH
Storage Temperature Range-10 ~ 50 ºC
Storage Humidity Range25 ~ 80% RH
Approx. External Dimension113 x 106 x 46 mm
Approx. External Weight0.35 kg
Optional Accessories2291 02 Carrying case for E series of miniature portable instruments
A case (B9604WM) that can hold the instrument as well as leads and other accessories is also available

Features

  • Useful for both high-sensitivity and large-volume measurements

DC: 30µA~30A, 0.3V~300V

AC: 500 µA~25 A, 3V~300V

  • Taut-band suspension system eliminates friction and provides strong resistance to shock impact.
  • Small and lightweight, with easy-to-read mirrored scale

Specifications - Model 2051 02

Max. Scale Value

0.3/1/3/10/30 mA DC
Approximate Internal Resistance and Consumed Power970/390/140/43/14 Ω
Operating PrinciplePermanent magnet moving coil type
ClassJIS C 1102: 1997 Class 1.0
Operating PositionHorizontal
Scale LengthApproximately 135 mm (Deflection Angle: 90°)
NeedleBladed Needle (red)
Linemax250V (Ammeters only)
Operating Temperature Range0 ~ 40 ºC
Operating Humidity Range30 ~ 75% RH
Storage Temperature Range-10 ~ 50 ºC
Storage Humidity Range25 ~ 80% RH
Approx. External Dimension113 x 106 x 46 mm
Approx. External Weight0.35 kg
Optional Accessories2291 02 Carrying case for E series of miniature portable instruments
A case (B9604WM) that can hold the instrument as well as leads and other accessories is also available

Features

  • Useful for both high-sensitivity and large-volume measurements

DC: 30µA~30A, 0.3V~300V

AC: 500 µA~25 A, 3V~300V

  • Taut-band suspension system eliminates friction and provides strong resistance to shock impact.
  • Small and lightweight, with easy-to-read mirrored scale

Specifications - Model 2051 03

Max. Scale Value

10/30/100/300/1000 mA DC
Approximate Internal Resistance and Consumed Power4/1.4/0.4/0.14/0.04 Ω
Operating PrinciplePermanent magnet moving coil type
ClassJIS C 1102: 1997 Class 1.0
Operating PositionHorizontal
Scale LengthApproximately 135 mm (Deflection Angle: 90°)
NeedleBladed Needle (red)
Linemax250V (Ammeters only)
Operating Temperature Range0 ~ 40 ºC
Operating Humidity Range30 ~ 75% RH
Storage Temperature Range-10 ~ 50 ºC
Storage Humidity Range25 ~ 80% RH
Approx. External Dimension113 x 106 x 46 mm
Approx. External Weight0.35 kg
Optional Accessories2291 02 Carrying case for E series of miniature portable instruments
A case (B9604WM) that can hold the instrument as well as leads and other accessories is also available

Features

  • Useful for both high-sensitivity and large-volume measurements

DC: 30µA~30A, 0.3V~300V

AC: 500 µA~25 A, 3V~300V

  • Taut-band suspension system eliminates friction and provides strong resistance to shock impact.
  • Small and lightweight, with easy-to-read mirrored scale

Specifications - Model 2051 04

Max. Scale Value

0.3/1/3/10/30 A DC
Approximate Internal Resistance and Consumed Power0.14/0.04/0.014/0.004/0.001 Ω
Operating PrinciplePermanent magnet moving coil type
ClassJIS C 1102: 1997 Class 1.0
Operating PositionHorizontal
Scale LengthApproximately 135 mm (Deflection Angle: 90°)
NeedleBladed Needle (red)
Linemax250V (Ammeters only)
Operating Temperature Range0 ~ 40 ºC
Operating Humidity Range30 ~ 75% RH
Storage Temperature Range-10 ~ 50 ºC
Storage Humidity Range25 ~ 80% RH
Approx. External Dimension113 x 106 x 46 mm
Approx. External Weight0.35 kg
Optional Accessories2291 02 Carrying case for E series of miniature portable instruments
A case (B9604WM) that can hold the instrument as well as leads and other accessories is also available

Features

  • Useful for both high-sensitivity and large-volume measurements

DC: 30µA~30A, 0.3V~300V

AC: 500 µA~25 A, 3V~300V

  • Taut-band suspension system eliminates friction and provides strong resistance to shock impact.
  • Small and lightweight, with easy-to-read mirrored scale

Specifications - Model 2051 05

Max. Scale Value

0.3/1/3/10/30 V DC
Approximate Internal Resistance and Consumed Power100µA(10kΩ/V)
Operating PrinciplePermanent magnet moving coil type
ClassJIS C 1102: 1997 Class 1.0
Operating PositionHorizontal
Scale LengthApproximately 135 mm (Deflection Angle: 90°)
NeedleBladed Needle (red)
Linemax250V (Ammeters only)
Operating Temperature Range0 ~ 40 ºC
Operating Humidity Range30 ~ 75% RH
Storage Temperature Range-10 ~ 50 ºC
Storage Humidity Range25 ~ 80% RH
Approx. External Dimension113 x 106 x 46 mm
Approx. External Weight0.35 kg
Optional Accessories2291 02 Carrying case for E series of miniature portable instruments
A case (B9604WM) that can hold the instrument as well as leads and other accessories is also available

Features

  • Useful for both high-sensitivity and large-volume measurements

DC: 30µA~30A, 0.3V~300V

AC: 500 µA~25 A, 3V~300V

  • Taut-band suspension system eliminates friction and provides strong resistance to shock impact.
  • Small and lightweight, with easy-to-read mirrored scale

Specifications - Model 2051 06

Max. Scale Value

3/10/30/100/300 V DC
Approximate Internal Resistance and Consumed Power100µA(10kΩ/V)
Operating PrinciplePermanent magnet moving coil type
ClassJIS C 1102: 1997 Class 1.0
Operating PositionHorizontal
Scale LengthApproximately 135 mm (Deflection Angle: 90°)
NeedleBladed Needle (red)
Linemax250V (Ammeters only)
Operating Temperature Range0 ~ 40 ºC
Operating Humidity Range30 ~ 75% RH
Storage Temperature Range-10 ~ 50 ºC
Storage Humidity Range25 ~ 80% RH
Approx. External Dimension113 x 106 x 46 mm
Approx. External Weight0.35 kg
Optional Accessories2291 02 Carrying case for E series of miniature portable instruments
A case (B9604WM) that can hold the instrument as well as leads and other accessories is also available

Features

  • Useful for both high-sensitivity and large-volume measurements

DC: 30µA~30A, 0.3V~300V

AC: 500 µA~25 A, 3V~300V

  • Taut-band suspension system eliminates friction and provides strong resistance to shock impact.
  • Small and lightweight, with easy-to-read mirrored scale

Specifications - Model 2051 11

Max. Scale Value

± 0.15/0.5/1.5/5/15 mA DC
Approximate Internal Resistance and Consumed Power970/390/140/43/14 Ω
Operating PrinciplePermanent magnet moving coil type
ClassJIS C 1102: 1997 Class 1.0
Operating PositionHorizontal
Scale LengthApproximately 135 mm (Deflection Angle: 90°)
NeedleBladed Needle (red)
Linemax250V (Ammeters only)
Operating Temperature Range0 ~ 40 ºC
Operating Humidity Range30 ~ 75% RH
Storage Temperature Range-10 ~ 50 ºC
Storage Humidity Range25 ~ 80% RH
Approx. External Dimension113 x 106 x 46 mm
Approx. External Weight0.35 kg
Optional Accessories2291 02 Carrying case for E series of miniature portable instruments
A case (B9604WM) that can hold the instrument as well as leads and other accessories is also available

Features

  • Useful for both high-sensitivity and large-volume measurements

DC: 30µA~30A, 0.3V~300V

AC: 500 µA~25 A, 3V~300V

  • Taut-band suspension system eliminates friction and provides strong resistance to shock impact.
  • Small and lightweight, with easy-to-read mirrored scale

Specifications - Model 2051 12

Max. Scale Value

± 0.3/1/3/10/30 mA DC
Approximate Internal Resistance and Consumed Power1170/400/135/40/14 Ω
Operating PrinciplePermanent magnet moving coil type
ClassJIS C 1102: 1997 Class 1.0
Operating PositionHorizontal
Scale LengthApproximately 135 mm (Deflection Angle: 90°)
NeedleBladed Needle (red)
Linemax250V (Ammeters only)
Operating Temperature Range0 ~ 40 ºC
Operating Humidity Range30 ~ 75% RH
Storage Temperature Range-10 ~ 50 ºC
Storage Humidity Range25 ~ 80% RH
Approx. External Dimension113 x 106 x 46 mm
Approx. External Weight0.35 kg
Optional Accessories2291 02 Carrying case for E series of miniature portable instruments
A case (B9604WM) that can hold the instrument as well as leads and other accessories is also available

Features

  • Useful for both high-sensitivity and large-volume measurements

DC: 30µA~30A, 0.3V~300V

AC: 500 µA~25 A, 3V~300V

  • Taut-band suspension system eliminates friction and provides strong resistance to shock impact.
  • Small and lightweight, with easy-to-read mirrored scale

Specifications - Model 2051 13

Max. Scale Value

± 5/15/50/150/500 mA DC
Approximate Internal Resistance and Consumed Power4/1.4/0.4/0.14/0.04 Ω
Operating PrinciplePermanent magnet moving coil type
ClassJIS C 1102: 1997 Class 1.0
Operating PositionHorizontal
Scale LengthApproximately 135 mm (Deflection Angle: 90°)
NeedleBladed Needle (red)
Linemax250V (Ammeters only)
Operating Temperature Range0 ~ 40 ºC
Operating Humidity Range30 ~ 75% RH
Storage Temperature Range-10 ~ 50 ºC
Storage Humidity Range25 ~ 80% RH
Approx. External Dimension113 x 106 x 46 mm
Approx. External Weight0.35 kg
Optional Accessories2291 02 Carrying case for E series of miniature portable instruments
A case (B9604WM) that can hold the instrument as well as leads and other accessories is also available

Features

  • Useful for both high-sensitivity and large-volume measurements

DC: 30µA~30A, 0.3V~300V

AC: 500 µA~25 A, 3V~300V

  • Taut-band suspension system eliminates friction and provides strong resistance to shock impact.
  • Small and lightweight, with easy-to-read mirrored scale

Specifications - Model 2051 14

Max. Scale Value

± 10/30/100/300/1000 mA DC
Approximate Internal Resistance and Consumed Power4/1.5/0.4/0.15/0.04 Ω
Operating PrinciplePermanent magnet moving coil type
ClassJIS C 1102: 1997 Class 1.0
Operating PositionHorizontal
Scale LengthApproximately 135 mm (Deflection Angle: 90°)
NeedleBladed Needle (red)
Linemax250V (Ammeters only)
Operating Temperature Range0 ~ 40 ºC
Operating Humidity Range30 ~ 75% RH
Storage Temperature Range-10 ~ 50 ºC
Storage Humidity Range25 ~ 80% RH
Approx. External Dimension113 x 106 x 46 mm
Approx. External Weight0.35 kg
Optional Accessories2291 02 Carrying case for E series of miniature portable instruments
A case (B9604WM) that can hold the instrument as well as leads and other accessories is also available

Features

  • Useful for both high-sensitivity and large-volume measurements

DC: 30µA~30A, 0.3V~300V

AC: 500 µA~25 A, 3V~300V

  • Taut-band suspension system eliminates friction and provides strong resistance to shock impact.
  • Small and lightweight, with easy-to-read mirrored scale

Specifications - Model 2051 15

Max. Scale Value

± 0.15/0.5/1.5/5/15 A DC
Approximate Internal Resistance and Consumed Power0.14/0.04/0.014/0.004/0.001 Ω
Operating PrinciplePermanent magnet moving coil type
ClassJIS C 1102: 1997 Class 1.0
Operating PositionHorizontal
Scale LengthApproximately 135 mm (Deflection Angle: 90°)
NeedleBladed Needle (red)
Linemax250V (Ammeters only)
Operating Temperature Range0 ~ 40 ºC
Operating Humidity Range30 ~ 75% RH
Storage Temperature Range-10 ~ 50 ºC
Storage Humidity Range25 ~ 80% RH
Approx. External Dimension113 x 106 x 46 mm
Approx. External Weight0.35 kg
Optional Accessories2291 02 Carrying case for E series of miniature portable instruments
A case (B9604WM) that can hold the instrument as well as leads and other accessories is also available

Features

  • Useful for both high-sensitivity and large-volume measurements

DC: 30µA~30A, 0.3V~300V

AC: 500 µA~25 A, 3V~300V

  • Taut-band suspension system eliminates friction and provides strong resistance to shock impact.
  • Small and lightweight, with easy-to-read mirrored scale

Specifications - Model 2051 16

Max. Scale Value

± 0.3/1/3/10/30 A DC
Approximate Internal Resistance and Consumed Power0.15/0.14/0.11/0.004/0.001 Ω
Operating PrinciplePermanent magnet moving coil type
ClassJIS C 1102: 1997 Class 1.0
Operating PositionHorizontal
Scale LengthApproximately 135 mm (Deflection Angle: 90°)
NeedleBladed Needle (red)
Linemax250V (Ammeters only)
Operating Temperature Range0 ~ 40 ºC
Operating Humidity Range30 ~ 75% RH
Storage Temperature Range-10 ~ 50 ºC
Storage Humidity Range25 ~ 80% RH
Approx. External Dimension113 x 106 x 46 mm
Approx. External Weight0.35 kg
Optional Accessories2291 02 Carrying case for E series of miniature portable instruments
A case (B9604WM) that can hold the instrument as well as leads and other accessories is also available

Features

  • Useful for both high-sensitivity and large-volume measurements

DC: 30µA~30A, 0.3V~300V

AC: 500 µA~25 A, 3V~300V

  • Taut-band suspension system eliminates friction and provides strong resistance to shock impact.
  • Small and lightweight, with easy-to-read mirrored scale

Specifications - Model 2051 17

Max. Scale Value

± 0.15/0.5/1.5/5/15 V DC
Approximate Internal Resistance and Consumed Power100µA(20kΩ/V)
Operating PrinciplePermanent magnet moving coil type
ClassJIS C 1102: 1997 Class 1.0
Operating PositionHorizontal
Scale LengthApproximately 135 mm (Deflection Angle: 90°)
NeedleBladed Needle (red)
Linemax250V (Ammeters only)
Operating Temperature Range0 ~ 40 ºC
Operating Humidity Range30 ~ 75% RH
Storage Temperature Range-10 ~ 50 ºC
Storage Humidity Range25 ~ 80% RH
Approx. External Dimension113 x 106 x 46 mm
Approx. External Weight0.35 kg
Optional Accessories2291 02 Carrying case for E series of miniature portable instruments
A case (B9604WM) that can hold the instrument as well as leads and other accessories is also available

Specifications - Model 2051 18

Max. Scale Value

± 0.3/1/3/10/30 V DC
Approximate Internal Resistance and Consumed Power100µA(10kΩ/V)
Operating PrinciplePermanent magnet moving coil type
ClassJIS C 1102: 1997 Class 1.0
Operating PositionHorizontal
Scale LengthApproximately 135 mm (Deflection Angle: 90°)
NeedleBladed Needle (red)
Linemax250V (Ammeters only)
Operating Temperature Range0 ~ 40 ºC
Operating Humidity Range30 ~ 75% RH
Storage Temperature Range-10 ~ 50 ºC
Storage Humidity Range25 ~ 80% RH
Approx. External Dimension113 x 106 x 46 mm
Approx. External Weight0.35 kg
Optional Accessories2291 02 Carrying case for E series of miniature portable instruments
A case (B9604WM) that can hold the instrument as well as leads and other accessories is also available

Features

  • Useful for both high-sensitivity and large-volume measurements

DC: 30µA~30A, 0.3V~300V

AC: 500 µA~25 A, 3V~300V

  • Taut-band suspension system eliminates friction and provides strong resistance to shock impact.
  • Small and lightweight, with easy-to-read mirrored scale

Specifications - Model 2051 19

Max. Scale Value

± 1.5/5/15/50/150 V DC
Approximate Internal Resistance and Consumed Power100µA(20kΩ/V)
Operating PrinciplePermanent magnet moving coil type
ClassJIS C 1102: 1997 Class 1.0
Operating PositionHorizontal
Scale LengthApproximately 135 mm (Deflection Angle: 90°)
NeedleBladed Needle (red)
Linemax250V (Ammeters only)
Operating Temperature Range0 ~ 40 ºC
Operating Humidity Range30 ~ 75% RH
Storage Temperature Range-10 ~ 50 ºC
Storage Humidity Range25 ~ 80% RH
Approx. External Dimension113 x 106 x 46 mm
Approx. External Weight0.35 kg
Optional Accessories2291 02 Carrying case for E series of miniature portable instruments
A case (B9604WM) that can hold the instrument as well as leads and other accessories is also available

Features

  • Useful for both high-sensitivity and large-volume measurements

DC: 30µA~30A, 0.3V~300V

AC: 500 µA~25 A, 3V~300V

  • Taut-band suspension system eliminates friction and provides strong resistance to shock impact.
  • Small and lightweight, with easy-to-read mirrored scale

Specifications - Model 2051 20

Max. Scale Value

± 3/10/30/100/300 V DC
Approximate Internal Resistance and Consumed Power100µA(10kΩ/V)
Operating PrinciplePermanent magnet moving coil type
ClassJIS C 1102: 1997 Class 1.0
Operating PositionHorizontal
Scale LengthApproximately 135 mm (Deflection Angle: 90°)
NeedleBladed Needle (red)
Linemax250V (Ammeters only)
Operating Temperature Range0 ~ 40 ºC
Operating Humidity Range30 ~ 75% RH
Storage Temperature Range-10 ~ 50 ºC
Storage Humidity Range25 ~ 80% RH
Approx. External Dimension113 x 106 x 46 mm
Approx. External Weight0.35 kg
Optional Accessories2291 02 Carrying case for E series of miniature portable instruments
A case (B9604WM) that can hold the instrument as well as leads and other accessories is also available

Features

  • Useful for both high-sensitivity and large-volume measurements

DC: 30µA~30A, 0.3V~300V

AC: 500 µA~25 A, 3V~300V

  • Taut-band suspension system eliminates friction and provides strong resistance to shock impact.
  • Small and lightweight, with easy-to-read mirrored scale

Specifications - Model 2052 01

Max. Scale Value

0.5/1/2.5 mA AC
Approximate Internal Resistance and Consumed Power3 V
Operating PrincipleRectifier type (approximating RMS rectifier type for 15~300V)
ClassJIS C 1102: 1997 Class 1.5
Operating PositionHorizontal
Scale LengthApproximately 135 mm (Deflection Angle: 90°)
NeedleBladed Needle (red)
Linemax250V (Ammeters only)
Operating Temperature Range0 ~ 40 ºC
Operating Humidity Range30 ~ 75% RH
Storage Temperature Range-10 ~ 50 ºC
Storage Humidity Range25 ~ 80% RH
Approx. External Dimension113 x 106 x 46 mm
Approx. External Weight0.35 kg
Optional Accessories2291 02 Carrying case for E series of miniature portable instruments
A case (B9604WM) that can hold the instrument as well as leads and other accessories is also available

Features

  • Useful for both high-sensitivity and large-volume measurements

DC: 30µA~30A, 0.3V~300V

AC: 500 µA~25 A, 3V~300V

  • Taut-band suspension system eliminates friction and provides strong resistance to shock impact.
  • Small and lightweight, with easy-to-read mirrored scale

Specifications - Model 2052 02

Max. Scale Value

2.5/5/10 mA AC
Approximate Internal Resistance and Consumed Power3 V
Operating PrincipleRectifier type (approximating RMS rectifier type for 15~300V)
ClassJIS C 1102: 1997 Class 1.5
Operating PositionHorizontal
Scale LengthApproximately 135 mm (Deflection Angle: 90°)
NeedleBladed Needle (red)
Linemax250V (Ammeters only)
Operating Temperature Range0 ~ 40 ºC
Operating Humidity Range30 ~ 75% RH
Storage Temperature Range-10 ~ 50 ºC
Storage Humidity Range25 ~ 80% RH
Approx. External Dimension113 x 106 x 46 mm
Approx. External Weight0.35 kg
Optional Accessories2291 02 Carrying case for E series of miniature portable instruments
A case (B9604WM) that can hold the instrument as well as leads and other accessories is also available

Features

  • Useful for both high-sensitivity and large-volume measurements

DC: 30µA~30A, 0.3V~300V

AC: 500 µA~25 A, 3V~300V

  • Taut-band suspension system eliminates friction and provides strong resistance to shock impact.
  • Small and lightweight, with easy-to-read mirrored scale

Specifications - Model 2052 03

Max. Scale Value

10/25/50 mA AC
Approximate Internal Resistance and Consumed Power3 V
Operating PrincipleRectifier type (approximating RMS rectifier type for 15~300V)
ClassJIS C 1102: 1997 Class 1.5
Operating PositionHorizontal
Scale LengthApproximately 135 mm (Deflection Angle: 90°)
NeedleBladed Needle (red)
Linemax250V (Ammeters only)
Operating Temperature Range0 ~ 40 ºC
Operating Humidity Range30 ~ 75% RH
Storage Temperature Range-10 ~ 50 ºC
Storage Humidity Range25 ~ 80% RH
Approx. External Dimension113 x 106 x 46 mm
Approx. External Weight0.35 kg
Optional Accessories2291 02 Carrying case for E series of miniature portable instruments
A case (B9604WM) that can hold the instrument as well as leads and other accessories is also available

Features

  • Useful for both high-sensitivity and large-volume measurements

DC: 30µA~30A, 0.3V~300V

AC: 500 µA~25 A, 3V~300V

  • Taut-band suspension system eliminates friction and provides strong resistance to shock impact.
  • Small and lightweight, with easy-to-read mirrored scale

Specifications - Model 2052 04

Max. Scale Value

50/100/250 mA AC
Approximate Internal Resistance and Consumed Power3 V
Operating PrincipleRectifier type (approximating RMS rectifier type for 15~300V)
ClassJIS C 1102: 1997 Class 1.5
Operating PositionHorizontal
Scale LengthApproximately 135 mm (Deflection Angle: 90°)
NeedleBladed Needle (red)
Linemax250V (Ammeters only)
Operating Temperature Range0 ~ 40 ºC
Operating Humidity Range30 ~ 75% RH
Storage Temperature Range-10 ~ 50 ºC
Storage Humidity Range25 ~ 80% RH
Approx. External Dimension113 x 106 x 46 mm
Approx. External Weight0.35 kg
Optional Accessories2291 02 Carrying case for E series of miniature portable instruments
A case (B9604WM) that can hold the instrument as well as leads and other accessories is also available

Features

  • Useful for both high-sensitivity and large-volume measurements

DC: 30µA~30A, 0.3V~300V

AC: 500 µA~25 A, 3V~300V

  • Taut-band suspension system eliminates friction and provides strong resistance to shock impact.
  • Small and lightweight, with easy-to-read mirrored scale

Specifications - Model 2052 05

Max. Scale Value

3/7.5/15 V AC
Approximate Internal Resistance and Consumed Power1 mA
Operating PrincipleRectifier type (approximating RMS rectifier type for 15~300V)
ClassJIS C 1102: 1997 Class 1.5
Operating PositionHorizontal
Scale LengthApproximately 135 mm (Deflection Angle: 90°)
NeedleBladed Needle (red)
Linemax250V (Ammeters only)
Operating Temperature Range0 ~ 40 ºC
Operating Humidity Range30 ~ 75% RH
Storage Temperature Range-10 ~ 50 ºC
Storage Humidity Range25 ~ 80% RH
Approx. External Dimension113 x 106 x 46 mm
Approx. External Weight0.35 kg
Optional Accessories2291 02 Carrying case for E series of miniature portable instruments
A case (B9604WM) that can hold the instrument as well as leads and other accessories is also available

Features

  • Useful for both high-sensitivity and large-volume measurements

DC: 30µA~30A, 0.3V~300V

AC: 500 µA~25 A, 3V~300V

  • Taut-band suspension system eliminates friction and provides strong resistance to shock impact.
  • Small and lightweight, with easy-to-read mirrored scale

Specifications - Model 2052 06

Max. Scale Value

15/30/75 V AC
Approximate Internal Resistance and Consumed Power1 mA
Operating PrincipleRectifier type (approximating RMS rectifier type for 15~300V)
ClassJIS C 1102: 1997 Class 1.5
Operating PositionHorizontal
Scale LengthApproximately 135 mm (Deflection Angle: 90°)
NeedleBladed Needle (red)
Linemax250V (Ammeters only)
Operating Temperature Range0 ~ 40 ºC
Operating Humidity Range30 ~ 75% RH
Storage Temperature Range-10 ~ 50 ºC
Storage Humidity Range25 ~ 80% RH
Approx. External Dimension113 x 106 x 46 mm
Approx. External Weight0.35 kg
Optional Accessories2291 02 Carrying case for E series of miniature portable instruments
A case (B9604WM) that can hold the instrument as well as leads and other accessories is also available

Features

  • Useful for both high-sensitivity and large-volume measurements

DC: 30µA~30A, 0.3V~300V

AC: 500 µA~25 A, 3V~300V

  • Taut-band suspension system eliminates friction and provides strong resistance to shock impact.
  • Small and lightweight, with easy-to-read mirrored scale

Specifications - Model 2052 07

Max. Scale Value

75/150/300 V AC
Approximate Internal Resistance and Consumed Power1 mA
Operating PrincipleRectifier type (approximating RMS rectifier type for 15~300V)
ClassJIS C 1102: 1997 Class 1.5
Operating PositionHorizontal
Scale LengthApproximately 135 mm (Deflection Angle: 90°)
NeedleBladed Needle (red)
Linemax250V (Ammeters only)
Operating Temperature Range0 ~ 40 ºC
Operating Humidity Range30 ~ 75% RH
Storage Temperature Range-10 ~ 50 ºC
Storage Humidity Range25 ~ 80% RH
Approx. External Dimension113 x 106 x 46 mm
Approx. External Weight0.35 kg
Optional Accessories2291 02 Carrying case for E series of miniature portable instruments
A case (B9604WM) that can hold the instrument as well as leads and other accessories is also available

Features

  • Useful for both high-sensitivity and large-volume measurements

DC: 30µA~30A, 0.3V~300V

AC: 500 µA~25 A, 3V~300V

  • Taut-band suspension system eliminates friction and provides strong resistance to shock impact.
  • Small and lightweight, with easy-to-read mirrored scale

Specifications - Model 2053 01

Max. Scale Value

0.25/0.5/1 A AC
Approximate Internal Resistance and Consumed Power1/1/1 VA
Operating PrincipleMoving iron type
ClassJIS C 1102: 1997 Class 1.5
Operating PositionHorizontal
Scale LengthApproximately 135 mm (Deflection Angle: 90°)
NeedleBladed Needle (red)
Linemax250V (Ammeters only)
Operating Temperature Range0 ~ 40 ºC
Operating Humidity Range30 ~ 75% RH
Storage Temperature Range-10 ~ 50 ºC
Storage Humidity Range25 ~ 80% RH
Approx. External Dimension113 x 106 x 46 mm
Approx. External Weight0.35 kg
Optional Accessories2291 02 Carrying case for E series of miniature portable instruments
A case (B9604WM) that can hold the instrument as well as leads and other accessories is also available

Features

  • Useful for both high-sensitivity and large-volume measurements

DC: 30µA~30A, 0.3V~300V

AC: 500 µA~25 A, 3V~300V

  • Taut-band suspension system eliminates friction and provides strong resistance to shock impact.
  • Small and lightweight, with easy-to-read mirrored scale

Specifications - Model 2053 02

Max. Scale Value

1/2 5/5 A AC
Approximate Internal Resistance and Consumed Power0.9/0.8/0.7 VA
Operating PrincipleMoving iron type
ClassJIS C 1102: 1997 Class 1.5
Operating PositionHorizontal
Scale LengthApproximately 135 mm (Deflection Angle: 90°)
NeedleBladed Needle (red)
Linemax250V (Ammeters only)
Operating Temperature Range0 ~ 40 ºC
Operating Humidity Range30 ~ 75% RH
Storage Temperature Range-10 ~ 50 ºC
Storage Humidity Range25 ~ 80% RH
Approx. External Dimension113 x 106 x 46 mm
Approx. External Weight0.35 kg
Optional Accessories2291 02 Carrying case for E series of miniature portable instruments
A case (B9604WM) that can hold the instrument as well as leads and other accessories is also available

Features

  • Useful for both high-sensitivity and large-volume measurements

DC: 30µA~30A, 0.3V~300V

AC: 500 µA~25 A, 3V~300V

  • Taut-band suspension system eliminates friction and provides strong resistance to shock impact.
  • Small and lightweight, with easy-to-read mirrored scale

Specifications - Model 2053 03

Max. Scale Value

5/10/25 A
Approximate Internal Resistance and Consumed Power0.6/0.9/2.3 VA
Operating PrincipleMoving iron type
ClassJIS C 1102: 1997 Class 1.5
Operating PositionHorizontal
Scale LengthApproximately 135 mm (Deflection Angle: 90°)
NeedleBladed Needle (red)
Linemax250V (Ammeters only)
Operating Temperature Range0 ~ 40 ºC
Operating Humidity Range30 ~ 75% RH
Storage Temperature Range-10 ~ 50 ºC
Storage Humidity Range25 ~ 80% RH
Approx. External Dimension113 x 106 x 46 mm
Approx. External Weight0.35 kg
Optional Accessories2291 02 Carrying case for E series of miniature portable instruments
A case (B9604WM) that can hold the instrument as well as leads and other accessories is also available

Features

  • Useful for both high-sensitivity and large-volume measurements

DC: 30µA~30A, 0.3V~300V

AC: 500 µA~25 A, 3V~300V

  • Taut-band suspension system eliminates friction and provides strong resistance to shock impact.
  • Small and lightweight, with easy-to-read mirrored scale